> In areas with moderate outdoor temperatures. Anywhere that the heatpump is going through defrost cycles, that statement is likely false because the COP is likely 1 or less when that starts happening.
While heating, That isn't even a particularly efficient unit (EER 9), and not all all unusual for r410 (which is basically banned for new sales in the USA since jan 1st)
But it has a 150W pan heater, but I don't think that is its primary defrost mode, at least its not going to be at 50k btu at those temperatures unless its also really dry. The pan heater is probably to just assure that the coil melt water doesn't build up in the base pan.
For most of the forced air systemms in the USA, the deforst mode is as I mentioned triggered via outdoor coil temp/runtimes and somewhere below an ambient of ~30F, which will be a coil temp of ~20F. The exact algorithm changes from AC unit to unit, but you get say 20 mins of heating, and then it will flip to 5 mins of AC while not running the oudoor fan, where an electric (or maybe gas) furance will heat the indoor air after it flows over the indoor coil which is cooling the air. So its a double wammy, its taking 5+ mins of operation back at an even higher wattage.
AKA the COP goes negative for 5 minuites... Which will pull the SEER numbers down pretty hard, and that unit actually has pretty poor numbers for being variable speed compressors/etc.(edit: should be SCOP, since SEER(2) is just the ac side, that unit looks to be optimized for heating. Either way, depending on which efficienty spec you pay attention to, the 'problem' tends to be that the SCOP/HSPF/etc numbers are calculated using 'moderate' temp data, so below freezing temps are a minority of the calculation)
I poked around a bit looking for the install/service guide for that unit but didn't find one detailing the defrost algorithm.
Not your parent. We had a Fujitsu AOU15RLS3 installed ~10 years ago. 25.3 SEER apparently, EER 13.9. Also r410A. We mainly got it for AC in summer but we'll take the heating of course. Pretty cold winters here.
Minimum Outdoor Temperature for Heating: -5°F
Yeah that's about as cold as it's right now actually. During the day!
We'll definitely use the propane fireplace in winter, especially when the power goes out, which has happened more frequently in recent years, as "proper winter" has given way to more freeze / thaw type stuff with ice storms.
Modern heat pumps have a COP close to 2 at 5F/-15C while still delivering 50k+ BTUs. Here's one example: https://ashp.neep.org/#!/product/68628/7/25000/95/7500/0///0